This bar serves to notify visitors of important

Front elevation of a blue 40 ft Magi Safe blast resistant module

Engineered BRM solutions | New-build supply

Custom Blast Resistant Modules

MagOffshore designs and manufactures application-specific blast resistant modules with the structure, access, electrical, HVAC, fire and gas, communication and workspace systems defined for each operating environment.

01

Defined blast performance10 psi blast load with 200 ms duration for the 40 ft configuration shown

02

Integrated BRM systemsStructure, electrical, HVAC, fire and gas, data and workspace scope

03

DNV design verification40 ft design reviewed and found compliant with DNV-ST-E272

Product overview and technical scope

What Is a Blast Resistant Module?

A blast resistant module (BRM) is a prefabricated steel building engineered for a specified blast load and duration. It provides an enclosed working environment for personnel and operational activities in energy and industrial facilities. Unlike a standard portable building, a BRM is designed as an integrated system in which the structure, access points and building services are coordinated around the intended use, occupancy and installation conditions.

Two blue blast resistant modules with recessed HVAC equipment in the manufacturing facility
Blast protectionDefined pressure and duration

Structural response is engineered against the specified blast criteria.

Structural systemSteel envelope and protected access

The frame, walls, roof, floor and doors work together as one load-resisting system.

Flexible configurationSize, layout and occupancy

Dimensions, internal arrangements and access points are adapted to the intended application.

Integrated systemsReady for operational fit-out

Electrical, HVAC, fire and gas, communications and workspace systems can be incorporated.

Integrated scope

Blast Resistant Module Design and Integrated Systems

A BRM is more than a blast-rated steel enclosure. Its structural, electrical and building systems can be configured around the installation conditions, occupancy and operational requirements.

Blast-Resistant Structure

The steel frame, walls, roof, floor and access systems are engineered around the specified blast load and response criteria.

  • Custom dimensions and internal layouts
  • Specified blast pressure and duration
  • Integrated lifting and transport provisions

Hazardous-Area Electrical

Electrical systems can be configured for the available power supply, area classification and equipment requirements.

  • ATEX/IECEx options for exposed equipment
  • Single-phase or three-phase configurations
  • Distribution, lighting, outlets and concealed cabling

HVAC, Fire and Gas

Climate control and safety systems are coordinated with occupancy, ambient conditions and the required protection scope.

  • Duty-based heating and cooling capacity
  • Smoke, heat and gas detection options
  • Call points, audible and visual alarms, and extinguishers

Communications and Workspace

Data connectivity and interior arrangements are configured around occupancy and day-to-day operational needs.

  • Data outlets positioned to suit the layout
  • Industrial network junction and distribution options
  • Workstations, power outlets, lighting and storage

MagOffshore Standard 40ft BRM Interiors

BRM Interiors for Personnel and Operations

The 40 ft BRM interior provides a usable workspace with lighting, air conditioning, power outlets, data connections, fire detection and accessible building systems.

10-personworkstation capacity
10 RJ45data outlets specified
Fire & gasdetection and alarm scope
BRM interior with long workstation, lighting, air conditioning and fire equipment

A clearer engineering conversation

From Blast Criteria to a Configured BRM

Every BRM starts with the site duty. Defining the operating environment early helps align the structural design, integrated systems, verification and documentation before quotation.

Start with Your Design Inputs
  1. 01

    Define the duty

    Share location, application, occupancy and dimensional constraints.

  2. 02

    Confirm design criteria

    Provide blast load and duration, temperature range, fire rating and hazardous-area requirements.

  3. 03

    Coordinate systems

    Align power, HVAC, fire and gas, communications, access and interior needs.

  4. 04

    Agree documentation

    Confirm the required verification, inspection, quality and FAT documentation.

New-build BRM supply

Blast Resistant Modules for Operators, EPCs and Procurement Teams

MagOffshore supplies new-build modules to organizations that need a coordinated technical package. Rental and used-unit services are not offered.

Facility Operators

For teams defining operational, safety and occupancy requirements.

EPC Contractors

For multidisciplinary packages that require coordinated technical inputs and documentation.

Engineering Integrators

For engineered modules that must fit a wider facility and systems scope.

Procurement Teams

For new-build sourcing, specification review and commercial quotation.

Before you inquire

Frequently Asked Questions

What is a blast resistant module used for?

A blast resistant module is a prefabricated steel building engineered for a defined blast load and duration. It provides an enclosed working environment for personnel and operational activities at energy and industrial sites.

Can a BRM be customized?

Yes. Module size, blast criteria, occupancy, access, electrical supply, HVAC duty, fire and gas systems, communications, interior arrangement and required documentation are confirmed for each order.

What does the DNV verification cover?

The supplied DNV Design Verification Report states that the documented 40 ft BRM design was reviewed and found compliant with DNV-ST-E272 - Equipment Assemblies. Requirements for other configurations are confirmed separately.

What information should we send for a quotation?

Share the installation location, application, required dimensions, blast criteria, occupancy, hazardous-area classification, electrical supply, HVAC duty, fire and gas requirements, communication needs, quantity and required documentation.

Do you offer rental or used blast resistant modules?

No. MagOffshore supplies new-build equipment and does not provide rental or used-unit services.

Request a Blast Resistant Module Design Review


Send the information you already have for a technical BRM review. Our team can assess the required module scope, identify missing inputs and define the next engineering, verification and documentation steps.


Blast criteria and design temperature

Size, occupancy and intended use

Electrical, HVAC and hazardous-area requirements

Fire, gas, communication and documentation scope